PATIENTS WITH COCHLEAR IMPLANTS IN THE OR – ISSUES AND CONCERNS

Authors

  • Brian Blakley

Abstract

Safety standards for patients with cochlear implants are difficult to find. Safety standards are, in fact, constantly evolving as more information becomes available. This article provides an overview of current philosophies and guidelines for most medical/surgical interventions, with emphasis on the operating room environment, as indicated by the three manufacturers authorized to market cochlear implants in Canada.

Author Biography

Brian Blakley

Dr. Brian W. Blakley, MD, PhD, FRCSC, is a professor and former chairman of the Department of Otolaryngology, University of Manitoba, in Winnipeg. He sub-specializes in otology (diseases of the ear) maintaining surgical, medical and research interests.

References

NIH consensus conference. Cochlear implants in

adults and children. JAMA 1995;274:1955-61.

Balkany T, Hodges AV, Luntz M. Update on

cochlear implantation. Otolaryngol Clin North

Am 1996;29:277-89.

Burgio P. Safety considerations of cochlear

implantation. Otolaryngol Clin North Am

;19:237-47.

Webb RL, Clark GM, Shepherd RK, Franz BK,

Pyman BC. The biologic safety of the Cochlear

Corporation multiple-electrode intracochlear

implant. Am J Otol 1988;9:8-13.

Clark G. Cochlear implants in children: safety

as well as speech and language. Int J Pediatr

Otorhinolaryngol 2003;67 Suppl 1:S7-20.

Gamble R. Info for CI. Personal

communication. In: Blakley B, ed., 2008.

Physician's Package insert for Nucleus 24

cochlear implants with Contour or contour

Advance electrode. Melbourne, Australia:

Cochlear Corporation, 2005:2-3.

O.R. Support Notes 4.14.2003

www.bionicear.com: Advanced Bionics, 2003:23.

Shepherd RK, McCreery DB. Basis of electrical

stimulation of the cochlea and the cochlear

nucleus. Adv Otorhinolaryngol 2006;64:186-205.

Ralston A, Stevens G, Mahomudally E,

Ibrahim I, Leckie E. Cochlear implants: response

to therapeutic irradiation. Int J Radiat Oncol Biol

Phys 1999;44:227-31.

Klenzner T, Lutterbach J, Aschendorff A,

Pedersen P, Stecker M, Laszig R. The effect of

large single radiation doses on cochlear implant

function: implications for radiosurgery. Eur Arch

Otorhinolaryngol 2004;261:251-5.

Klenzner T, Knapp F, Rohner F, von

Wallenberg E, Mauch H, Pedersen P, Aschendorff

A, Laszig R, Lutterbach J. Influence of ionizing

radiation on nucleus 24 cochlear implants. Otol

Neurotol 2005;26:661-7.

www.arthrocare.com. Plasma Knife /

Coblation. Austin, TX: Arthrocare Corporation,

Antonelli PJ, Baratelli R. Cochlear implant

integrity after adenoidectomy with Coblation and

monopolar electrosurgery. Am J Otolaryngol

;28:9-12.

Aurora RN, Casey KR, Kristo D, Auerbach S,

Bista SR, Chowdhuri S, Karippot A, Lamm C,

Ramar K, Zak R, Morgenthaler TI. Practice

parameters for the surgical modifications of the

upper airway for obstructive sleep apnea in

adults. Sleep 2010;33:1408-13.

Chou CK, McDougall JA, Can KW. Absence

of radiofrequency heating from auditory implants

during magnetic resonance imaging.

Bioelectromagnetics 1995;16:307-16.

Gubbels SP, McMenomey SO. Safety study of

the Cochlear Nucleus 24 device with internal

magnet in the 1.5 Tesla magnetic resonance

imaging scanner. Laryngoscope 2006;116:865-71.

DeLuca SA, Castronovo FP, Jr. Hazards of

magnetic resonance imaging. Am Fam Physician

;41:145-6.

Obler R, Kostler H, Weber BP, Mack KF,

Becker H. Safe electrical stimulation of the

cochlear nerve at the promontory during

functional magnetic resonance imaging. Magn

Reson Med 1999;42:371-8.

Weber BP, Goldring, J.E., Koestler, H.,

Tziviskos, G., Battmer, R., Lenarz, T. Magnetic

Resonance Imaging Compatibility Testing of the

Clarion 1.2 Cochlear Implant. AmJ Otol

;19:584-90.

Dyer RK, Jr., Nakmali D, Dormer KJ.

Magnetic resonance imaging compatibility and

safety of the SOUNDTEC Direct System.

Laryngoscope 2006;116:1321-33.

Sonnenburg RE, Wackym PA, Yoganandan N,

Firszt JB, Prost RW, Pintar FA. Biophysics of

cochlear implant/MRI interactions emphasizing

bone biomechanical properties. Laryngoscope

;112:1720-5.

Fritsch MH, Mosier KM. MRI compatibility

issues in otology. Curr Opin Otolaryngol Head

Neck Surg 2007;15:335-40.

Downloads

Published

2011-09-01

How to Cite

Blakley, B. (2011). PATIENTS WITH COCHLEAR IMPLANTS IN THE OR – ISSUES AND CONCERNS. Operating Room Nurses Association of Canada Journal, 29(3). Retrieved from https://ornacjournal.ca/index.php/ornac/article/view/12359